Due to the large difference in temperature between North and South, mainly in the winter, there are significant differences in the outdoor temperature in some northern regions. Therefore, it is necessary to install floor heating to bring warmth to the interior. When we buy back to the floor, followed by the warm installation, how to install the floor heating ? How to install a warmer and more energy-efficient? Let's find out together! First, how to install the floor heating: 1, first assembled a good water collector, according to a good position and marked height of the home, the water dispenser is straight and firmly close to the wall, and fixed with expansion bolts. In order to prevent the loss of heat, it is necessary to put a special insulation cover for the pipe connecting the manifold to the installation room. 2. Before you start to warm the floor, you must sweep away the dust on the floor of the house. If there are irregularities on the floor or debris, clean the ground to ensure the formation of the ground. Then, you need to conduct an on-site inspection of the entire home to determine the wall. Furnace and manifold installation location. 3, use the hot water pipe as the main pipe to warm, temperature control line is buried in the location of the water collector, put some related temperature control line also put together around to facilitate connection, installation should be straight and tidy. 4. When the insulation board is laid, it should be smooth, and the joints should be tight when they are jointed. The reflective film should not be laid. Cover tightly, no leakage of insulation board or ground phenomenon. 5, laying floor heating pipe according to the actual situation of the distance and direction of the pipe to operate, the pipe spacing should be kept parallel, and use plastic clips in accordance with the drawings pipe fixed to the extruded board or with a strap fixed to the wire mesh. 6. After the floor heating pipe is laid, it is necessary to conduct hydrostatic pressure test on the pipeline and ensure that the pipeline is open. The method is to inject clean water from the water injection valve, the test pressure is 1.5 to 2 times the working pressure, but not less than 0.6Mpa, and the pressure drop within 1 hour is not more than 0.05Mpa. If it does not leak, it will be qualified. 7. To keep the horizontal line of the house at a height, be sure to bury all the steel mesh underneath, and there must be no leakage. When laying concrete, all use artificial pressure and compaction, in the doorway, aisles, floor drains and other locations must be marked to prevent misconduct in the later construction of heating pipes. 8, install the bottom of the boiler excuse to use hoses. Second, how to install the floor heating can be more energy-efficient: The floor heating system water is not to be replaced, but it has a very important condition. It must meet the standard, that is, the height of the floor. If the new water is changed every year, it is easy to produce scale. Because of the fouled water, it is not easy to continue scaling afterwards, and the heat sink system can be easily selected. In the case of satisfying the floor heating load, floor heating is achieved through low-temperature radiation heating. In addition to the selection of floor heating boilers and accessories, the construction details and quality of floor heating are also important. Summary: How to install the floor heating and how to install the floor heating can be more energy-efficient, Xiao Bian introduced here, want to know more home information please continue to pay attention to this site. How to install the floor heating Auxiliary systems under [SEALMANN" trademark, mainly used in series of solutions for API Seal Support Systems,Rotor Clip,Advanced Materials,Mechanical Sealing Support Systems Ningbo FLK Technology Co., Ltd. , https://www.flk-global.com
682 standard (PLAN21, 31, 52, 53A, 53B and 53C etc..), with products of reservoir, hydraulic
cyclone separator, heat exchanger etc. Different kinds of gauges and switches can be equipped for
monitor or alarm as required.
Our goal is to provide customers with more reliable product solutions to ensure that the
mechanical seals are running under a safe, stable, long-term reliable environment.